SG12 sampler complete

Item number: 00133

The sampler SG12 incl. power supply has been developed for the steady state sampling of hazardous substances.
It is particularly suitable for the measurement of inorganic fibrous particles such as asbestos, men-made mineral fibres (MMMF) and other inorganic fibres in indoor air and outside air according to VDI 3492 and ISO 14966 with a volume flow of 8 l/min.
Furthermore
it is suitable for steady state sampling of inhalable and respirable dust with a volume flow of 10 l/min.

The sampler SG12 has been developed for the steady state sampling of fibres and dusts when high volume flows are needed and high flow resistance must be overcome, in particular for fibre measurement according to VDI 3492. The nominal volume flow range is 3.5 to 10 l/min. Smaller volume flows up to approx. 2 l/min are possible with lower constancy.
 

Category: Alle Messgeräte


4.061,47 €

including 19% VAT., plus shipping (Versicherter Versand)

Shipping time: 2 - 4 workdays

set


Description

The sampler SG12 incl. power supply has been developed for the steady state sampling of hazardous substances.
It is particularly suitable for the measurement of inorganic fibrous particles such as asbestos, men-made mineral fibres (MMMF) and other inorganic fibres in indoor air and outside air according to VDI 3492 and ISO 14966 with a volume flow of 8 l/min.
Furthermore
it is suitable for steady state sampling of inhalable and respirable dust with a volume flow of 10 l/min.

The sampler SG12 has been developed for the steady state sampling of gases and dusts when high volume flows are needed and high flow resistance must be overcome, in particular for fibre measurement according to VDI 3492. The suction tube and suction curved tubes enable the necassary sampling at a height of 1.2 to 1.5m.

The sampler is equipped with a powerful rotary vane pump, which generates a nearly pulsation-free vacuum and can overcome high flow resistances. The sampler is easy to operate and covers a wide adjustable flow range from approx. 3.5 to 10 l/min without any gap. The requirements on a constant volume flow with changing flow resistance with fault indication and automatic shut-off are fulfilled through the automatic volume flow regulation over the complete range.

Specifications:
- Nominal flow rate: 3.5-10 l/min (± 5 %)
- Adjustable flow rate: approx. 2-12 l/min
- Integrated flow meter
- Electronic flow regulation
- Sampling time programmable, automatic switching-off, battery-buffered data storage
- Display shows actual capacity of the battery, running time of errors
- Easy way of using the keys
- Shows percentage burden of the pump
- Dimension (WxDxH): 170x280x82 mm
- Weight: 3700 g

Construction and Operation:
The sampler SG12 is equipped with a rotary vane pump which produces an almost pulsation-free vacuum. The desired volume flow is adjustable between approx. 2-12 l/min. The selected volume flow remains sufficiently constant over the sampling duration. This is ensured by the installed volume flow regulation which compensates the otherwise usual decrease of volume flow as a result of an increased flow resistance (e.g. filter resistance) or changed operating voltage. The sampling parameters are programmable and are readable on the 2x8 digits LCD display. The keys can be locked. In case the pump cannot maintain the selected volume flow as a result of too much flow resistance, the device will switch off. The runtime of the pump up to switch-off is stored, so that the sampling duration can be read later. The complete operation sequence and the regulation are controlled by a microprocessor. The reasons for switching-off will be shown at the display.

Scope of supply:
- Sampler SG12
- Power cable
- 2x suction tube
- Hose connection
- 5x Outletfilter
- Operating instructions (D/E)

Available accessories:
- various float type flow meters
- sampling head VDI 3492 (Item.No.: 00040)
- GSP10 sampling head for inhalable dust (Item.No.: 00092)
- FSP10 sampling head for respirable dust (Item.No.: 00064)
- PAK/ PCB sampling head according VDI 2463 BI.7 (Item.No. 02199).

Of course you will find further equipment at our online store. If you have any questions, please use our contact form or just call us.

Shipping information:
- No marking necessary

Volume flow: 3,500 - 10,000 mL/min
Operating range: Stationary
A-dust fraction: suitable
E-dust fraction: suitable
Fibre measurement according to VDI 3492 (e.g. asbestos, MMMF, glas fibre): particularly suitable
Ex-Protection: No ex-protection
fibre measurement according to DGUV 213-546 raster electronical method: not suitable
fibre measurement according to DGUV 213-531 light microscopy method: not suitable
Welding fume: not suitable
PAK / PCB according to VDI 2463 p. 7: suitable
Gases (VOC, formaldehyde, etc.): not suitable
Product weight: 4,25 Kg

Question on item

Question on item